Elemental Scientific, Inc.
     Sample Introduction Technology for ICPMS and ICPAES
HomeProductsConsultingApp DataDistributorsContact Us
 

Literature References

 
     Laser Ablation Systems
       
  Microflow PFA Nebulizer  

Determination of Dibutyltin in Sediments Using Isotope Dilution Liquid Chromatography-Inductively Coupled Plasma Mass Spectrometry
Yong-Hyeon Yim et al. Bulletin of the Korean Chemistry Society, 440 2005, 26(3), 440-446 [abstract] [link]

Spatial mapping of droplet velocity and size for direct and indirect nebulization in plasma spectrometry
Kahen K et al. Analytical Chemistry 2004 Dec 15, 76(24), 7194-7201 [abstract] [link]

Non-Metal Emission Detector for HPLC
Heather L. Peters, Department of Chemistry, Wake Forest University ; April 19, 2004 [abstract] [link]

Multi-Analyte Calibration Curve for High-Performance Liquid Chromatography with an Inductively Coupled Plasma Carbon Emission Detector
Peters H.L.; Hou X.; Jones B.T. Applied Spectroscopy, 2003 57(9), 1162-1166 [abstract] [link]

Determination of halogens in organic compounds by high resolution inductively coupled plasma mass spectrometry (HR-ICP-MS)
Bu X.; Wang T.; Hall G. Journal of Analytical Atomic Spectrometry, 2003, 18, 1443-1451 [abstract] [link]

Zircon (U-Th)/He thermochronometry: He diffusion and comparisons with 40Ar/ 39Ar dating
Reiners, P.W. et al. Geochimica et Cosmochimica Acta, 2004, 68(8), 1857-1887 [abstract] [link]

Determination of Re Isotopes in Geological Samples using the Agilent 7500s ICP-MS
Graham S.; Pearson N. Agilent ICP-MS Journal 2003 September, 17, 5 [abstract] [link]

Post-orogenic evolution of the Dabie Shan, eastern China , from (U-Th)/He and fission-track thermochronology
Reiners P.W. et al. American Journal of Science, 2003 June, 303, 489–518 [abstract] [link]

Analyzing Semiconductor Samples With the ELAN DRC II ICP Mass Spectrometer
Atomic Spectroscopy, 2003 March/April, 24(2), 37-39 [abstract]

Extremely light Li in orogenic eclogites: The role of isotope fractionation during dehydration in subducted oceanic crust
Zack T. et al., Earth and Planetary Science Letters, 2003 March, 208(3-4), 279-290 [abstract] [link]

Combined single-grain (U-Th)/He and U/Pb dating of detrital zircons from the Navajo Sandstone, Utah
Rahl J.M. et al. Geology, 2003, 31(9), 761-764 [abstract] [link]

Influence of wildfires on apatite and zircon (U-Th)/He ages
Sara Gran Mitchell and Peter W. Reiners, Geology 2003, 31(12), 1025-1028 [abstract] [link]

Using VPD and magnetic sector ICP-MS to characterize contaminants
D. Palsulich; K. Coyle; Weston L., Micro Magazine, 2002 June [abstract] [link]

Intra-annual variation in the stable oxygen and carbon and trace element composition of sclerosponges
P.K. Swart et al., Paleoceanography, 2002 September 10, 17(3), 1045 [abstract] [link]

Isotope Ratio Analysis of Low Abundance U Isotopes
Thermo Finnigan MAT GmbH, Element 2 Application Flash Report No. E 16, 2002 [abstract]

Iron Isotopic Composition of the Amazon River
B. Bergquist; E. Boyle, American Geophysical Union, 2002 Fall Meeting, abstract #OS12C-0290 [abstract] [link]

Measurement of Macro and Trace Elements in Plant Digests Using the 7500c ICP-MS System
K. Yamanaka; F. Fryer, Agilent Technologies Application Report 5998-4450EN, 2001 [abstract] [link]

A Beginner’s Guide to ICP-MS, Part II: The Sample-Introduction System
R. Thomas, Spectroscopy, 2001 May, 16(5), 56-60 [abstract] [link]

Analysis of Semiconductor Grade Sulfuric Acid Using the Agilent 7500s ICP-MS
M. Radle; T. J. Gluodenis; Agilent Technologies, Inc. Application 5988-3164EN, 2001 [abstract] [link]

Analysis of Trace Elements and Pb Isotope Ratios is Sclerosponge Skeletons Using Laser Ablation HR-ICP-MS
S. Thorrold; C. Latkoczy, Norfolk 2000 – 1st International Conference on HR-ICP-MS [abstract]

       
  Microflow PFA-20 Nebulizer  

Sr Isotopes by laser ablation PIMMS: Application to CPX from Samoan peridotite xenoliths
S. R. Hart; L. Ball; M. Jackson, Woods Hole Oceanographic Institution, WHOI Plasma Facility Open File Technical Report 11, June 2004 [abstract] [link]

Temperature and salinity effects on strontium incorporation in otoliths of larval spot (Leiostomus xanthurus)
G. B. Martin et al., Canadian Journal of Fisheries and Aquatic Sciences, 2004, 61(1): 34-42 [abstract] [link]

Evaluation of a single collector, double focusing sector field inductively coupled plasma mass spectrometer for the determination of U and Pu concentrations and isotopic compositions at trace level
Baglan et al., Journal of Radioanalytical and Nuclear Chemistry, 2004, 261(3) 609–617 [abstract] [link]

High-speed photographic study of an ICP during laser ablation: Comparison of droplets from a microconcentric nebulizer and solid particles from laser ablation
D. Aeschliman; S. Bajic, D. Baldwin, R. S. Houk, Journal of Analytical Atomic Spectrometry, 2003,  18(9): 1008 – 1014 [abstract]

Relationships between water, otolith, and scale chemistries of westslope cutthroat trout from the Coeur d'Alene River , Idaho : the potential application of hard-part chemistry to describe movements in fresh water
B. K. Wells et al., Transactions of the American Fisheries Society, 2003, 132:409–424 [abstract] [link]

Trace Metals in Pentane with the Agilent 7500c
E. Soffey, Agilent ICP-MS Journal 2002 August Issue 13 [abstract] [link]

The Determination of Impurities in Nitric Acid and Hydrofluoric Acid by ICP-MS
K. Yamanaka; J. Gomez; D. Potter, Agilent Technologies, Inc., Application Note Semiconductor,
5964-0320E, 2001 November 15 [abstract] [link]

Determination of trace metal impurities in isopropyl alcohol (IPA) using HR-ICP-MS
Finnigan MAT Application Flash Report No. E 5, 1999 April [abstract]

       
  Microflow PFA-50 Nebulizer  

Interfacing capillary electrophoresis with inductively coupled plasma mass spectrometry for redox speciation of plutonium
Ambard et al., Radiochimica Acta, 2005, 93(11): 665-673 [abstract] [link]

Evaluation of a single collector, double focusing sector field inductively coupled plasma mass spectrometer for the determination of U and Pu concentrations and isotopic compositions at trace level
Baglan et al., Journal of Radioanalytical and Nuclear Chemistry, 2004, 261(3): 609–617 [abstract] [link]

Ultra low-level measurements of actinides by sector field ICP-MS
Pointurier et al., Applied Radiation and Isotopes, 2004 60(2-4): 561–566 [abstract] [link]

Isotopic Data Pinpoint Iceman's Origins
C. Holden; Science, 2003, 302(5646): 759 - 761 [abstract] [link]

Determination of Boron 10/11-Ratio in Stainless Steels with ICP-MS
K. Prattes, G. Hochoertler, W. Wegscheider, Poster Presentation, 51st Chemists' Conference, CORUS, Birmingham, England, 30 August 2000 [abstract] [link]

ISIS II™, The Latest Generation Inert Sample Introduction Systems for ICPMS
TJA Solutions Technical Brief, S026TB Issue 1, 3/2000 [abstract] [link]

Measurement of 11B/10B ratios using the IsoProbe Multi-collector ICP-MS System and the new PFA-50 MicroFlow PFA Nebulizer [abstract] [link]
S. Meffan-Main, Z. Palacz, Micromass, Application Brief AB11 10/1999

       
  Microflow PFA-100 Nebulizer  

Determination of Impurities in Semiconductor Grade Hydrochloric Acid Using the Agilent 7500cs ICP-MS
J. Takahashi, Agilent Technologies Application Report 5989-4348EN, 2006 [abstract] [link]

Determination of Methyl Mercury in Water and Soil by HPLC-ICP-MS
D. Chen, M. Jing, X. Wang, Agilent Technologies Application Report 5989-3572EN, 2005 [abstract] [link]

Multi-element Analysis of Blood and Serum Samples by 7500ce
R. Wahlen, L. Evans, J. Turner, R. Hearn, Agilent ICP-MS Journal, Issue 24, 8/2005 [abstract] [link]

Determination of Pu in urine at ultratrace level by sector field inductively coupled plasma mass spectrometry
M. V. Zoriya, et al. International Journal of Mass Spectrometry, 1 April 2004, 232(3), 217-224 [abstract] [link]

Rapid multi-element analysis of groundwater by high-resolution inductively coupled plasma mass spectrometry
Z. Cheng, Y. Zheng, R. Mortlock, A. van Geen, Analytical and Bioanalytical Chemistry, 2004, 379(3):512-518 [abstract] [link]

Analysis of Impurities in Semiconductor Grad TMAZ Using the Agilent 7500cs ICPMS
J. Takahashi, K. Youno, Agilent Technologies Application 5988-9892EN, 7/2003 [abstract] [link]

Determination of Mercury in Microwave Digests of Foodstuffs by ICP-MS
J. Entwisle, American Laboratory, 2004, 36(6): 11-14 [abstract] [link]

The Elemental Composition of Some Marine Phytoplankton
T-Y. Ho, et al., Journal of Phycology, 2003, 39(6): 1145-1159 [abstract] [link]

Reaching SEMI Grade 5 Purity Levels in Hydrogen Peroxide With Dynamic Reaction Cell ICP-MS Technology
J-M. Collard, K. Kawabata, Y. Kishi, Atomic Spectroscopy, 2003, 24(2): 49-56 [abstract] [link]

Meteorites, Fossils, Rocks and Rivers
N. Rogers, Agilent ICP-MS Journal 16, Environmental Special Edition, 5/2003 [abstract] [link]

Lead isotope analysis of marine carbonates and seawater by multiple collector ICP-MS
M. K. Reuera, E. A. Boyleb, B. C. Grant, Chemical Geology 2003, 200 : 137-153 [abstract] [link]

A Comparison of GC–ICP-MS and HPLC–ICP-MS for the Analysis of Organotin Compounds
R. Wahlen, Agilent Technologies Inc., Application Note 5988-6697EN 10/2002 [abstract] [link]

Using Lead Isotope Ratios to Distinguish between Samples of the Traditional Chinese Medicine Dan-shen
D. Chen, Agilent Technologies Inc., Application Note 5988-7450EN, 7/2002 [abstract] [link]

Isotope Ratio Measurement of Uranium in Safeguards Environmental Samples by Inductively-Coupled Plasma Mass Spectrometry (ICP-MS)
M. Magara, et al., Journal of Nuclear Science and Technology, 2002, 39(4): 308-311 [abstract] [link]

Molecular Structure and Microstructure of PM2.5 Derived from Stationary and Mobile Fossil Fuel Sources
G. P. Huffman et al., Final technical report on research sponsored by the National Science Foundation under CRAEMS grant CHE-0089133 June 16, 2006[abstract] [link]

Determination of trace elements in filtered suspended marine particulate material by sector field HR-ICP-MS
J. T. Cullen, M. P. Field, R. M. Sherrell, Journal of Analytical Atomic Spectrometry, 2001, 16 : 1307 [abstract] [link]

Determination of Trace Elements in IPA by ICP-DRC-MS
O. Shikino, Y. Suzuki, K. Honda, Analytical Sciences, 2001, 17(Supplement i837) [abstract] [link]

Sulfur Isotope Ratios in PM2.5
J. Kyger, J. D. Robertson, Fuel Chemistry Division Preprints, 2001, 46(1) [abstract]

Determination of Ca Isotope Ratios in Urine: Medium or Low Resolution?
P. M. Field, Rutgers University, Norfolk 2000 - 1st International Conference on HR-ICP-MS, Abstracts A2, [abstract] [link]

Analysis of Mercury in Wastewater by ICP-MS using the Agilent 7500i
S. Wilbur, Agilent Technologies Inc., Application Note 5980-0248E, 2000 [abstract] [link]

       
  PFA-400 Nebulizer  

Ultrapure water for boron and silica sensitive laboratory applications
I. Kano, D. Darbouret, American Laboratory News January 2000 : 12-16 abstract] [link]

       
  PFA-ST Nebulizer  

How Low Can Impurities in Pure Water be Analyzed by ICP-MS?
K. Kawabata, Y. Kishi, Atomic Spectroscopy, 2003, 24(2): 73-77 [abstract] [link]

       
  Apex  

Simultaneous quantification of 17 trace elements in blood by dynamic reaction cell inductively coupled plasma mass spectrometry (DRC-ICP-MS) equipped with a high-efficiency sample introduction system
S. D’Ilio, et al. Analytica Chimica Acta, 10 October 2006, 579 (2), Pages 202-208 [abstract] [link]

Determination of trace elements in serum by dynamic reaction cell inductively coupled plasma mass spectrometry Developing of a method with a desolvating system nebulizer
S. D’Ilio, et. al. Analytica Chimica Acta, 28 July 2006, Vol. 573-574, 432-438 Instrumental Methods of Analysis -IMA 2005 [abstract] [link]

Determination of extremely low 236U/238U isotope ratios in environmental samples by sector-field inductively coupled plasma mass spectrometry using high-efficiency sample introduction
Sergei F. Boulyga, and Klaus G. Heumann, Journal of Environmental Radioactivity2006, 88 (1), Pages 1-10 [abstract] [link]

Determination of 234U/238U isotope ratios in environmental waters by quadrupole ICP-MS after U stripping from alpha-spectrometry counting sources
J. L. Mas, et al., nalytical and Bioanalytical Chemistry, 2006, 386(1): 152-160 [abstract] [link]

Inductively coupled plasma-sector field mass spectrometry with a high-efficiency sample introduction system for the determination of Pu isotopes in settling particles at femtogram levels
J. Zheng , M. Yamada, 2006, Talanta 69(5): 1246–1253 [abstract] [link]

Rapid determination of plutonium in urine using flow injection on-line preconcentration and inductively coupled plasma mass spectrometry
V. N. Epov, et al., Journal of Analytical Atomic Spectrometry, 2005, 20 : 424-430. [abstract] [link]

Micro-extraction procedures for the determination of Ra-226 in well waters by SF-ICP-MS
D. Larivière, et al., Analytica Chimica Acta, 2005, 528(2): 175-182 [abstract] [link]

Assessment of the accuracy of stable Fe isotope ratio measurements on samples with organic and inorganic matrices by high-resolution multicollector ICP-MS
R. Schoenberg, F. von Blanckenburg, International Journal of Mass Spectrometry, 2005, 242 : 257-272 [abstract] [link]

Measurement of Uranium Isotope Ratios in Undigested Urine using Apex Q
D. Wiederin, P. Watson, G. Etter, Elemental Scientific, presented at the 5th International Conference on Magnetic Sector Field ICP-MS, Omaha, Nebraska, USA, August 18-20, 2004 [abstract] [link]

Rapid and precise calcium isotope ratio determinations using the Apex-ACM desolvating inlet system with sector-field ICP-MS in low resolution
Elemental Scientific Inc. Apex Application Report APEX-ACM – Ca Ratios [abstract] [pdf]

High precision calcium isotope ratio measurements using a magnetic sector multiple collector inductively coupled plasma mass spectrometer
M. E. Wieser, et al., Journal of Analytical Atomic Spectrometry, 2004, 19(7): 844-851 f [abstract] [link]

Sensitivity study of the ThermoFinnigan Neptune MCICPMS using different inlet systems
J.B. Schwieters, C. Bouman, D. Tuttas, and M. Wieser, Goldschmidt Conference Abstracts 2003, A421 [abstract]

Protocols for accurate stable Fe isotope ratio measurements of samples with organic and inorganic matrices by high resolution multicollector ICP-MS
R. Schoenberg, F. von Blanckenburg, Institut für Mineralogie, Universität Hannover [abstract]
       
  PC3  

Analysis of Wastewater and Mine Tailing Samples Using Octopole Reaction System Agilent 7500cs for Sub Parts Per Billion Reporting Levels [abstract] [pdf]
Marshall Pattee, North Creek Analytical, Inc.

Analysis of Hexavalent Chromium From Alkaline Digestion EPA 3060A, Using Octopole Reaction System Agilent 7500cs [abstract] [pdf]
Marshall Pattee & Mustahsan Farooqui, North Creek Analytical, Inc.

       
  PFA Sample Introduction Systems  

X Series ICP-MS
Thermo Electron Corporation, BR40336_E 01/04C 2004 p.11 [abstract] [link]

7500cs Octopole Reaction System ICP-MS Technical Overview
Agilent Technologies, Inc., Technical Overview 5988-9881EN, 08/2003 [abstract] [link]

Agilent 7500cs Inductively Coupled Plasma Mass Spectrometer (ICP-MS) Data Sheet
Agilent Technologies, Inc., Application Note 5988-8991EN, 3/2003 [abstract] [link]

Analysis of Silicon Wafers Using the ELAN DRC ICP-MS
A. F. Porche, Y. Kishi, R. E. Wolf, Atomic Spectroscopy, 2003, 24(2): 42 [abstract]

Determination of Trace Metal Impurities in Semiconductor Grade Phosphoric Acid by High Sensitivity Reaction Cell ICP-MS
J. Takahashi, K. Youno, Agilent Technologies Inc., Application Note 5988-8901EN, 3/2003 [abstract] [link]

The Benefits of Dynamic Reaction Cell ICP-MS Technology to Determine Ultra Trace Metal Contamination Levels in High Purity Phosphoric and Sulfuric Acid
K. Kawabata, Y. Kishi, R. Thomas, Atomic Spectroscopy, 2003, 24(2): 57-65 [abstract] [link]

DRC-ICP-MS Analysis of Various Chemicals Used in the Semiconductor Industry
K. Kawabata, Y. Kishi, Atomic Spectroscopy, 2003, 24(2): 66-72 [abstract] [link]

Effect of Plasma Parameters on the Analysis of the Semiconductor Process
Y. Kishi, K. Kawabata, Atomic Spectroscopy, 24(2): 46-48 [abstract] [link]

Determination of Particulate and Dissolved Metals in Natural Waters
P. M. Field, 3rd International Conference on High Resolution Sector Field ICPMS 21, Atlanta, Georgia October 2nd-5th, 2002 [abstract] [link]

Determination of Trace Metal Impurities in Semiconductor-Grade Hydrogen Peroxide by ICP-MS
A. Gutierrez, J Takahashi, T. Gluodenis, Agilent Technologies Application Note 5988-5947EN, 4/2002 [abstract] [link]

Determination of Trace Metal Impurities in Semiconductor-Grade Hydrofluoric Acid
A. Gutierrez, J. Takahashi, T. Gluodenis, Agilent Technologies Application Note 5988-5421EN, 3/2002 [abstract] [link]

Uranium in Urine: Quantification and Isotope Ratio Determination
ThermoFinnigan, Element2 Application Flash Report No. E17, 2002 [abstract]

High-precision Ru isotopic measurements by multi-collector ICP-MS
H. Becker, C. Dalpe, R. J. Walker, Analyst, 2002, 127(6):775-780 [abstract] [link]

Lithium Isotope Measurements Using Neptune Multi-Collector ICP-MS
ThermoFinnigan, Neptune Application Flash Report No. N2 2001 [abstract]

Nd AND Hf Isotope Measurements Using a Double Focusing Multicollector ICPMS
ThermoFinnigan, Neptune Application Flash Report No. N1, 2001 [abstract]

Determination of Trace Elements in Clinical Samples by High-Resolution ICP-MS
ThermoFinnigan MAT GmbH, Element2 Application Flash Report No. E9 (2001) [abstract]

Determination of Ultra Trace Elements in Liquid Crystal by High Resolution ICP-MS
ThermoFinnigan MAT GmbH, Element2 Application Flash Report No. E8, 2001 [abstract]

Determination of Ultratrace Elements in Semiconductor Grade TMAH Developer
ThermoFinnigan MAT GmbH, Element2 Application Flash Report No. E7, 1999 [abstract]

High Precision Determination of Sr/Ca and Mg/Ca Elemental Ratios in Massive Coral Skeletons
H. Kuhnert, et al., ThermoFinnigan MAT GmbH, Element2 Application Flash Report No. E6, 1999 [abstract]

High Precision Measurement of Magnesium to Calcium and Strontium to Calcium Elemental Ratios
ThermoFinnigan MAT GmbH, Element2 Application Flash Report No. E4, 1999 [abstract]

Fast and Sensitive Multi-Element Quantification in Clinical Samples with Sector Field ICP-MS
J. Hinrichs, J-C. Aubry, J-M. Boeynaems [abstract]

       
  Aridus Upgrade  

Direct determination of ultra-trace levels of metals in fresh water using desolvating micronebulization and HR-ICP-MS: application to Lake Superior waters
M. P. Field, R. M. Sherrell, Journal of Analytical Atomic Spectrometry, 2003, 18(3): 254-259 [abstract] [link]

Precise and accurate determination of calcium isotope ratios in urine using HR-ICP-SFMS
M. P. Field, S. Shapses, M. Cifuentes, R. M. Sherrell, Atomic Spectrometry, 2003, 18(7): 727-733 [abstract] [link]

Direct determination of 10 trace metals in 50 m L samples of coastal seawater using desolvating micronebulization sector field ICP-MS
M. P. Field, J. T. Cullen, R. M. Sherrell, Journal of Analytica. Atomic Spectrometry 1999, 14 : 1425 [abstract] [link]

       
  Remote Aerosol Transfer System  

A First Look at a New Approach to On-line ICP-MS Measurement
PerkinElmer Sciex, Semiconductor News, 2003, 4 (1) [abstract] [link]

     

  Laser Ablation Systems  

Adding Nebulized Aerosol to Laser Ablated Aerosols
Dan Wiederin and Paul Watson, Elemental Scientific, presented at the 5th International Conference on Magnetic Sector Field ICP-MS, Omaha, Nebraska, USA, August 18-20, 2004 [abstract] [link]

       
 
   
  Elemental Scientific, Inc.
2440 Cuming St.
Omaha, NE 68131
Tel: +1.402.991.7800
Fax: +1.402.991.7799
Email: esi@icpms.com